Alameda County, CACompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 3974 Orchard Trl

Approved

Filed Nov 25, 2024 by Sam Calloway, Valley Septic Service · paper form read in and confirmed by staff

Report

Date of service
Nov 25, 2024
Tank size
1500 gal
Compartments
2
Gallons pumped
1337 gal
Sludge depth
27 in
Scum depth
6 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
Yes
Disposal site
Permitted land-application site
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 001-94-01114
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

3974 Orchard Trl
Owner: Avery Vance
Parcel 001-94-01114