El Dorado County, CACompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 3773 Turkey Hill Dr

Approved

Filed May 7, 2019 by Shawn Okafor, Northstar Wastewater · filed from phone

Report

Date of service
May 7, 2019
Tank size
1500 gal
Compartments
2
Gallons pumped
1358 gal
Sludge depth
31 in
Scum depth
3 in
Baffles in good condition
No
Effluent filter
Cleaned
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Outlet baffle missing
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 017-22-01129
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

3773 Turkey Hill Dr
Owner: Reese Brandt
Parcel 017-22-01129