Back to the septic review queue
Septic maintenance (pump-out): 5039 Laurel Trl
ApprovedFiled Dec 7, 2018 by Riley Brandt, Summit Wastewater. Filed from a phone.
Report
- Date of service
- Dec 7, 2018
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 901 gal
- Sludge depth
- 29 in
- Scum depth
- 3 in
- Baffles in good condition
- Yes
- Effluent filter
- Replaced
- Lids and risers secure
- Yes
- Disposal site
- County treatment plant
- Repair needed
- Yes
- Repair needed: describe
- Cracked lid
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Riley Brandt, current on the service date
- All required fields present
- Address matches parcel 051-47-01129
- Sludge is over a third of a typical tank depth; check for system failure.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
5039 Laurel Trl
Owner: Avery Wexler
Parcel 051-47-01129