← Septic review queue
Septic maintenance (pump-out) · 6769 Stone Gate Ct
Needs reviewFiled Nov 18, 2026 by Riley Harlow, Summit Wastewater · filed from phone
Report
- Date of service
- Nov 18, 2026
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 963 gal
- Sludge depth
- 29 in
- Scum depth
- 6 in
- Baffles in good condition
- Yes
- Effluent filter
- Replaced
- Lids and risers secure
- No
- Disposal site
- Regional wastewater plant
- Repair needed
- Yes
- Repair needed: describe
- Cracked lid
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 089-39-01045
- Sludge is over a third of a typical tank depth; check for system failure.
- Unsecured lids are a safety hazard.
- No photos attached.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Property
6769 Stone Gate Ct
Owner: Parker Nguyen
Parcel 089-39-01045