Septic maintenance (pump-out) · 9559 Spring Branch Trl

Approved

Filed Jun 21, 2020 by Casey Whitcomb, Keystone Pumping Co · filed from phone

Report

Date of service
Jun 21, 2020
Tank size
1500 gal
Compartments
1
Gallons pumped
1316 gal
Sludge depth
31 in
Scum depth
8 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
Yes
Disposal site
County treatment plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 089-93-01315
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

9559 Spring Branch Trl
Owner: Riley Ashby
Parcel 089-93-01315