← Septic review queue
Septic maintenance (pump-out) · 517 Pine Knoll Rd
ApprovedFiled May 13, 2026 by Cameron Danner, Heritage Wastewater · paper form read in and confirmed by staff
Report
- Date of service
- May 13, 2026
- Tank size
- 1250 gal
- Compartments
- 2
- Gallons pumped
- 1231 gal
- Sludge depth
- 31 in
- Scum depth
- 3 in
- Baffles in good condition
- No
- Effluent filter
- None present
- Lids and risers secure
- Yes
- Disposal site
- Regional wastewater plant
- Repair needed
- No
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 009-15-01270
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- No photos attached.
- Result: passing. Next due date resets when approved.
Decision
Approved by Auto-approved (no flags). The property's next due date is set and the owner gets a receipt.
Property
517 Pine Knoll Rd
Owner: Jamie Ellery
Parcel 009-15-01270