Brevard County, FLCompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 1848 Sycamore Rd

Approved

Filed Sep 16, 2020 by Hayden Ashby, Valley Wastewater · paper form read in and confirmed by staff

Report

Date of service
Sep 16, 2020
Tank size
1250 gal
Compartments
2
Gallons pumped
1157 gal
Sludge depth
29 in
Scum depth
9 in
Baffles in good condition
Yes
Effluent filter
None present
Lids and risers secure
Yes
Disposal site
County treatment plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
2 attached
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 009-33-01313
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by Auto-approved (no flags). The property's next due date is set and the owner gets a receipt.

Property

1848 Sycamore Rd
Owner: Quinn Whitcomb
Parcel 009-33-01313